Introduction:
The drillers knowledgebase is a questions and answers area for the drilling community to learn and share knowledge and experience. This particular question has been moved from the old drillers.com website and the answers are displayed in the body of the article. If you have a further comment then feel free to add it in the comments section at the bottom of the page. If you want to ask a new question then there is a question entry box further down.
QUESTION:
We classify the drillpipe as brand new, premium, class 2, etc. It is based on wear of pipe body. I like to know when we should reject a drillpipe if box or pin of tool joint wear to a limit.
(Question asked by Kyi Lwin)
ANSWER:
You can refer to API 7G:
You can find tables that provides Recommended Min TJ OD based on torsional strength of Box and Drill Pipe.
Cheers, Larry
(Answered by Yunchuan)
Submit your question to be published on my-spread.com
If you have a technical question, you ought to head over to our drilling specialists nirvana, my-spread.com. It is a free-to-join forum with around 2000 members including some of the most knowledgeable engineers and geologists in the world. Most, if not all major oil and service companies are represented there.
(Or scroll down to add an answer or read further comments and answers)